Project detailsName, client, your steel rate
Only your own figure is used — InstaBOQ adds no rate.
Add every beam, column, slab and footing, enter the section, cover and bars, and get cutting lengths, bar counts and steel weight by diameter. Bend deductions, hooks and development length follow IS 2502 / SP 34 and IS 456. Need it in Excel with formulas? Download the free bar bending schedule Excel template.
Nothing here yet. Add your first member. Each member is one beam, column, slab (and so on) with its bars; if you have six identical beams, add one and set "identical members" to 6.
The example is a beam, a column and a footing.
Assumptions used
- Bend deductions (× bar diameter, per bend)
- 45° = 1d, 90° = 2d, 135° = 3d (SP 34). If you give a bend radius, 45° and 90° bends use the exact geometric deduction 2(r + d)·tan(θ/2) − θ(r + d/2) instead; hooks always use the table.
- Hook length (× bar diameter)
- 90° = 12d, 135° = 10d
- Minimum hook length (IS 13920)
- 75mm floor, applied to the 135° hook only
- Unit weight (IS 1786)
- d² / 162 kg per metre
- Cutting lengths
- rounded half-up to the nearest 10mm, once
- Development length
- Ld = 0.87 fy × d / (4 × 1.6 × τbd), IS 456 Cl 26.2.1, used exactly — not rounded to a whole multiple of d, which can fall short of the code by up to half a diameter.
- Tie leg arrangements resolved
- 2 legs = 1 × closed_rect; 3 legs = 1 × closed_rect, 1 × single_leg; 4 legs = 1 × closed_rect, 2 × single_leg
- Stock length for splicing
- 12000mm. A bar longer than this is split into stock-length pieces and the lap steel at each splice is ADDED to the total length and weight — so for a spliced bar, total length is more than cutting length × bar count, by design.
- Splice lap length
- the greater of Ld and 30d (IS 456 Cl 26.2.5.1(c), flexural tension). If a grade pair has no tabulated bond stress, a bar needing a splice is reported as uncomputable rather than spliced with a zero lap.
- Closer stirrups / ties near the ends
- If you give an end-zone length and spacing, the run is counted as end zone + middle + end zone without counting the boundary bars twice. Zone lengths are never assumed.
- Bent-up (cranked) bars
- two 45° cranks, each adding 0.42 × the centreline offset D' (member depth − 2 × cover − bar diameter), on top of the anchored straight length. Centreline basis, so no extra bend deduction. Not yet hand-verified.
- Continuous beams
- Bottom bars per span: bent down into end supports, Ld/3 past the face at interior supports (IS 456 Cl 26.2.3.3(a)). Top bars continuous, bent down into both end supports, spliced with billed laps when over stock length. Not yet hand-verified.
- Column bars
- Floor height + lap carried up; a crank into the column above adds the slope length at 1 in 6; ground-floor starter bars add the footing depth less cover and an L-foot, with the 90° bend deducted. Circular columns: hoops are π × centreline diameter plus hooks; a helix adds 1.5 turns at each end.
- Lintel, staircase, pile cap
- Lintel bars run opening + bearing each side less cover; the stair is a one-flight waist slab with main bars along the slope (√(run² + rise²)); the pile cap is a plain block with a bottom mat and an optional straight top mat. Step concrete, pile heads and side-face bars are not modelled.
- Steel density ranges (kg/m³)
- beams 100–200, columns 150–280; other members are shown without a verdict — no published range has been checked for them, and a guessed range would be worse than none
A calculation aid, not a design. It applies standard IS conventions to the numbers you enter and does not check that they satisfy any code requirement. A qualified engineer must check and sign off the schedule before any bar is cut.